VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations English only
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

Cronbach's alpha= 0.64 to 0.92

B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

ICC= 0.82 to 0.96

C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)
2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

Each section was selected from a literature consultation and interviews with rheumatologists and orthopaedic surgeons specialized in spine surgery

B. Construct Validity:
Structural validity
Not Tested
Hypotheses-testing Not Tested
Cross-cultural validity Tested
Brief Description
C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)