VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations <5 European languages (English)
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

0.95

B. Reliability intraobserver or test-retest Not Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

high >0.95

C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)

SEM and MDC non available

2. VALIDITY
A. Content validity: face validity Not Tested
Expert opinion (relevance and
comprehensiveness) (Describe)
B. Construct Validity:
Structural validity
Not Tested
Hypotheses-testing Not Tested
Cross-cultural validity Tested
Brief Description
C. Criterion validity Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)

Strong correlation with doctor’s global assessment, patient’s global assessment and roland morris questionnaire