VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations <5 European languages (English)
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

0.84

B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

0.83-0.95

C. Reliability interobserver or Measurement error Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)

- Reliability Inter  0.99

- Population of pelvic girdle pain

SEM 6.34

MDC 17.6

2. VALIDITY
A. Content validity: face validity Not Tested
Expert opinion (relevance and
comprehensiveness) (Describe)
B. Construct Validity:
Structural validity
Not Tested
Hypotheses-testing Not Tested
Cross-cultural validity Not Tested
Brief Description
C. Criterion validity Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)

Functional Status Questionnaire, Oswestry Low Back Disability Questionnaire