VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations >=5 European languages (English)
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

For full scale Chronbach's = 0,92.  (Rumination = 0.85-.091; Magnification = 0.66-0.75; Helplessness = 0.78-0.87)

B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

Excellent short-term test-retest reliability (ICC=0,94)

C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)

Standard error of measurement = 2,874

2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

The PCS contributed significant unique variance to the prediction of pain intensity

B. Construct Validity:
Structural validity
Not Tested
Hypotheses-testing Not Tested
Cross-cultural validity Tested
Brief Description
C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)