VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations >=5 European languages (English)
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

Cronbach’s alpha was 0.94

B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

The ICC for the OMPSQ overall score was 0.89 (95% confidence interval [CI] 0.79‒0.95). For the overall scores of the SPS, the ICC was 0.87 (95% CI 0.74‒0.93).

The instrument has satisfactory test-retest reliability (0.83)

C. Reliability interobserver or Measurement error Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)

The standard error of the mean, expressed as percentage of the mean, was 6.6% for the SPS and 10% for the OMPSQ.

2. VALIDITY
A. Content validity: face validity Not Tested
Expert opinion (relevance and
comprehensiveness) (Describe)
B. Construct Validity:
Structural validity
Not Tested
Hypotheses-testing Tested
Cross-cultural validity Tested
Brief Description
C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)