VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations English only
Observations

Cost to use: Flexigrip (10 m), around €20-40.

 

1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

Internal consistency was measured in 52 patients with RA and showed a Cronbach’s α of 0.65

B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

Intraobserver reliability: 0.985

Interobserver reliability: 0.948

C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)
2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

Items for the GAT were selected from those in the Grip Function Test that were sensitive to change and optimally represented different grip types in patients with RA receiving active hand training

B. Construct Validity:
Structural validity
Not Tested
Hypotheses-testing Tested
Cross-cultural validity Not Tested
Brief Description
C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)