VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

Cronbach's ranged 0,77-0,83

B. Reliability intraobserver or test-retest Not Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)
C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)
2. VALIDITY
A. Content validity: face validity Not Tested
Expert opinion (relevance and
comprehensiveness) (Describe)
B. Construct Validity:
Structural validity
Tested
Hypotheses-testing Not Tested
Cross-cultural validity Not Tested
Brief Description

PCA & exploratory FA with Factor loading. Under the 2-factor structure, for people who had high control, the items of perceived difficulty and self-efficacy represented 2 separate constructs, but for people who had low control, these items had cross factor loadings.

C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)