VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations English only
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

The person-separation index, used to measure internal consistency on the final 20-item instrument, was reported as 0.84.

B. Reliability intraobserver or test-retest Not Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

The TIQ-20 test-retest intraclass correlation coefficient was 0.76 (95% CI 0.61-0.85).

C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)
2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

Twenty-five people with tophaceous gout (22 men; median age, 66 years; median gout disease duration, 26 years) participated in semistructured interviews that explored their experiences and perceptions of tophi, as the first step to developing a patient-reported Tophus Impact Questionnaire.

B. Construct Validity:
Structural validity
Tested
Hypotheses-testing Tested
Cross-cultural validity Not Tested
Brief Description

The TIQ-20 responses fit the Rasch model and demonstrated unidimensionality, adequate precision, absence of differential item functioning, and adequate person separation index.

C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)