VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations >=5 European languages (English)
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

The internal-consistency reliabilities of these short-form measures were lower, but not much lower, than their full-length versions. Reliability Cronbach's coefficients for the multi-item health scales ranged from 0.81 to 0.88

B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

Test-retest reliability was 0.96 (ICC)

C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)
2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

The panel of experts concluded that the items appear valid. The MOS-20 survey achieves breadth and depth of measurement, while permitting self-administration in only 3-4 minutes. By virtue of its reduction of respondent burden by 80% relative to the lengthier measures from which it was derived, this short-form survey offers a more practical approach to patient health assessment.

B. Construct Validity:
Structural validity
Tested
Hypotheses-testing Tested
Cross-cultural validity Not Tested
Brief Description

The PCA analysis identified four factors (loadings 0.54-0.74).

C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)