VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations >=5 European languages (English)
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)
α = 0.90.
Similar high internal consistency was found for all the 12 items of the scale (α= 0.92)
B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

Sperarman coefficients ranged form 0.70 for "fatigue" to 0.95 for concentration difficulties

C. Reliability interobserver or Measurement error Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)

ANOVA with patients and raters as independent factors.

Correlation coefficient= 0.98 for the total scale and a range of 0.86-0.97 for individuals items.

2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

Frequently Symptom Checker

B. Construct Validity:
Structural validity
Not Tested
Hypotheses-testing Not Tested
Cross-cultural validity Not Tested
Brief Description
C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)