VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations <5 European languages (English)
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

Cronbach's alpha coefficients for the 4 subscales varied between 0.85 and 0.95 (English version)

B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

Weighted kappa coefficients ranged from Kw = 0.56 to 0.77.

English version:

Weighted kappa coefficients (K(w)) ranged between 0.77 and 0.93 for the 4 subscales and between 0.74 and 0.83 for the 4 single items without systematic variations (p > 0.05).

C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)
2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

The questionnaire was developed by healthcare providers involved in the clinical care of patients with myositis, and by ten patients selected to represent men and women and various disease duration, disease activity, and life situations. 

English version:

 Correlations between the median of subscales/single items of the MAP and the HAQ and disease effect on well-being were r(s) = 0.69 and r(s) = 0.68, respectively, with lower correlations to the MMT (r(s) = -0.35), and the FI-2 (r(s) = -0.29 to -0.47) and disease activity measures (r(s) = 0.36-0.41)

 

B. Construct Validity:
Structural validity
Not Tested
Hypotheses-testing Tested
Cross-cultural validity Not Tested
Brief Description
C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)