VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations English only
Observations
1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

0.893-0.967

B. Reliability intraobserver or test-retest Not Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)
C. Reliability interobserver or Measurement error Not Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)
2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

Item selection and reduction was achieved based on patients as well as an interdisciplinary group of physicians, nurses, and health educators, in addition to clinometric and psychometric methods. The latter included Rasch and internal consistency reliability analyses.

B. Construct Validity:
Structural validity
Tested
Hypotheses-testing Not Tested
Cross-cultural validity Not Tested
Brief Description

Patient reported tender spots correlated significantly with the physician's scores (r= 0.818).

Content construct assessment of the PROMs-functional disability and QoL revealed significant correlation (P< 0.01) with both SF-36 and Euro QoL scores. (r is not shown)

C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)