VALIDATION DATA

MEASUREMENT PROPERTIES
Limitations >=5 European languages (English)
Observations

Translated versions can be found on the official website: http://dash.iwh.on.ca/translations. Researchers and commercial organisations wishing to use the translated measure should contact the developers.

1. RELIABILITY
A. Internal Consistency Tested
Cronbach's (Describe)

Cronbach’s  alpha=0.92–0.98 (0.92 to 0.95 for the QuickDASH)

B. Reliability intraobserver or test-retest Tested
Continuous scores: intraclass
correlation coefficient (ICC)
Dichotomus: Cohen kappa (Describe)

The DASH demonstrates high test-retest reliability, with reported ICCs ranging from 0.89 to 0.98 for the DASH and 0.90 to 0.94 for the Quick-

DASH

C. Reliability interobserver or Measurement error Tested
Standard error of measurement (SEM),
smallest detectable change (SDC) or
Limits of agreement (LoA) (Describe)

SEM=2.8–5.2; Minimally detectable change 95% CI: 7.9–12.8 (average 10.8).

2. VALIDITY
A. Content validity: face validity Tested
Expert opinion (relevance and
comprehensiveness) (Describe)

Draft items were identified by literature review (821 items were reduced to 67 plus 3 new) because of content overlap or off-target questions determined by a group consensus). Patient data were analyzed by different item to total correlation techniques, comparison to clinimetric ranking and clinical judgment, resulting in the final 30-item version

B. Construct Validity:
Structural validity
Tested
Hypotheses-testing Tested
Cross-cultural validity Tested
Brief Description

Rasch analysis and factor analysis were used (Cano, 2011; Franchignoni, 2010) which highlighted areas for potential improvement for the use of the DASH.

C. Criterion validity Not Tested
Comparison with a 'gold standard' Continuous scores:
correlations, ROC curves Dichotomus:
Sensitivity & Specificity (Describe)